Introduction:Because the lithium battery will discharge naturally, if it is not used for a long time, the battery will be damaged. To ensure long-life, the battery needs charging for maintenance once a month.
Battery operating temperature requirements:-10 °C ~ 50 °C
Battery charging temperature requirements: 0 °C ~ 40 °C
Battery storage temperature requirements:-20 °C ~ 30 °C
Step:
1. Visual Inspection: Check the appearance of the battery is intact, no damage, bulging or leakage of liquid.
2. Check Power: Press the power indicator button to check the current power.
3. Insert battery: Insert the battery into the fusion splicer.
4. Connect the adapter: Insert the adapter into the power port of the fusion splicer, check the battery display panel, confirm that the battery display starts flashing - flashing means the machine is charging.
5. Charging to 3 cells: stop charging after the 3RD FLASH OF BATTERY POWER INDICATOR (battery for long-term storage or transportation should be kept in medium or low power state) .
6. Done