Common Function

1. Arc Test

Function Introduction: Used for fusion strength calibration according to current splicing environment, splicing material and electrode state.

1.1. To ensure stable fusion quality, an arc test should be done regularly

1.2. Please do an arc test if the environment temperature, humidity or air pressure change dramatically

1.3. Please do an arc test after replacing the electrodes

Step: Arc test

2. Language Setting

Function Introduction: Used to display the fusion splicer menu language

3. Parameters Check

Function Introduction: Display fusion parameters self-check results, the normal values as follows:

· Correct Value:10

· SM Parameter:145~175

· MM Parameter:125~155

· Check Status: Done

4. Arc force

Function Introduction: "Fiber end face inspection" is not available during the fusion splicing process

· OFF: “Fiber end quality check” (default)

· ON: No “Fiber end quality check”

5.Cleave Arc

6.User Password Setting

Function Introduction: For client password settings

The current state:

· OFF: No need for a password when turning on

· ON: Needs a password to turn on

Change Password: Press “Menu” to enter, type the new password and press “Menu ” to save

7.Done